We offer free standard shipping Australia-wide for all orders over $100! Thanks for supporting Aussie businesses!

MG MASTER LV – Low Voltage BMS 72-96V/500A-M12

$3,399.00

Product in Stock

Description

Model No MGMLV962500-M12
Description

MG MASTER LV – Low Voltage BMS 72-96V/500A-M12

Voltage 96V
Width 426mm
Height 225mm
Length/Breadth/Depth 117mm
Weight 4600g
Brand mg energy15850091510743

Previously MGMLV961500-M12

MG Energy Systems Master LV Series – Next Generation LiIon Battery Solutions

96V 500A M12 Low-Voltage battery management control unit for battery systems 12V – 96V, With CAN-Bus communication

  • Compact design
  • Current monitoring
  • Easy installation
  • DC Distribution
  • Fuse Box
  • Intergrated Pre-Charging
  • Plug and Play
  • Internal event logging
Protecting, monitoring and controlling a battery system is very important to create a safe, reliable and easy-to-use system. The MG Master LV unit of the battery system protects the connected battery modules against over-charging, over-discharging, over-temperature, under-temperature and controls the balancing of the battery cells. Besides a safety function, the Master LV monitors and tracks other important parameters to give insight in the battery status and energy consumption. The integrated DC distribution, fuse holders and safety contactor make it easy to install and require less cables and external equipment.

Specifications:

  •     Communication: CAN-Bus (NMEA2000, SMA, custom on request)
  •     Humidity: Max. 95% (non-condensing)
  •     Operating temperature range: -20°C to + 50ºC
  •     Protection class: IP22
  •     Max. number of batteries in Parallel: 48
  •     Max. number of batteries in series: 2 (= 48V)
  •     M12 connection
webhigh voltage mg 158 DC Distribution
One of the unique features, which makes installation much easier, is an integrated DC distribution system with fuse holders. Flexible system configurations are possible for small to large systems of up to 96 connected battery modules.
M12 and RJ45
The communication connections between the batteries and Master LV can be either with economical RJ45 cables or more robust M12 cables. Up to 96V both options are available. The M12 connectors integrate an interlock loop to monitor connections. This interlock can be used to switch of the internal safety contactor hardwired by an external emergency button.
webconnect mg
websettings mg 158 Diagnostic tool software
Battery system diagnostics are important during commissioning, system testing, service, maintenance and trouble shooting. The diagnostic tools provide all the detailed information about the battery system. Main values, like voltage, current and State-Of-Charge, can be viewed and logged to a file. Moreover, detailed battery information can be shown such as cell voltages, all temperature sensor, firmware version etc. Besides this information also history values and stored events can be read from the Master. To create more flexibility, settings can be configured, for example CAN-Bus protocol selection or adding a function to a dedicated output.
Monitoring and Control
Critical parameters are monitored by the Master LV such as cell voltages and temperatures of each connected battery module. A set of limits is determined providing boundaries. Several boundaries are set for each of the monitored parameters. First a control boundary which controls chargers or loads. Second a warning limit and third a critical fail which opens the safety contactors interrupting the power path from the batteries to loads and chargers. A well integrated system never opens its safety contactors during normal operation.
webmonitoring mg 158
victronconnect icon2 VictronConnect Compatible

Data Sheets: MGMLV961500-M126224

If you have any questions please don’t hesitate to contact us and we’ll be happy to assist. For more information on the MG Master LV – Low Voltage BMS visit this link

MG MASTER LV – Low Voltage BMS 72-96V/500A-M12

Categories ,
0
    0
    Your Cart
    Your cart is empty